TANDEM study with thermoluminescent materials in standard diagnostic beams
| dc.contributor.author | MAIA, ANA F. | pt_BR |
| dc.contributor.author | CALDAS, LINDA V.E. | pt_BR |
| dc.coverage | Nacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:44:50Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:48:06Z | |
| dc.date.available | 2014-07-15T13:44:50Z | pt_BR |
| dc.date.available | 2014-07-30T11:48:06Z | |
| dc.date.issued | 2007 | pt_BR |
| dc.description.abstract | Tandem systems formed with different thermoluminescent dosemeters were evaluated in standard diagnostic radiation beams. The utilized materials are commercially available, and the aim of this study was to carry out a performance comparison. The results show that the energy dependence of the materials, except TLD-100, were very high. Therefore, there are several possibilities of pair combinations forming a tandem system, but all of them using TLD-100 with a high energy dependent TL material. For all pair combinations evaluated in this study, the differences in the measurement ratios of subsequent energy values were always higher than 14%. The main differences among these tandem systems were in the dose sensitivity. The more advantageous TLD pair, among all evaluated, was TLD-100 and TLD-200, but several other combinations were also very efficient. | |
| dc.format.extent | 97-100 | pt_BR |
| dc.identifier.citation | MAIA, ANA F.; CALDAS, LINDA V.E. TANDEM study with thermoluminescent materials in standard diagnostic beams. <b>Revista Brasileira de Pesquisa e Desenvolvimento</b>, v. 9, n. 3, p. 97-100, 2007. Disponível em: http://repositorio.ipen.br/handle/123456789/5156. | |
| dc.identifier.fasciculo | 3 | pt_BR |
| dc.identifier.issn | 0104-7698 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0002-7362-2455 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5156 | pt_BR |
| dc.identifier.vol | 9 | pt_BR |
| dc.relation.ispartof | Revista Brasileira de Pesquisa e Desenvolvimento | pt_BR |
| dc.rights | openAccess | en |
| dc.subject | beams | pt_BR |
| dc.subject | dosimetry | pt_BR |
| dc.subject | luminescent dosemeters | pt_BR |
| dc.subject | phosphorus | pt_BR |
| dc.subject | radiation protection | pt_BR |
| dc.subject | thermoluminescent dosemeters | pt_BR |
| dc.subject | thermoluminescent dosimetry | pt_BR |
| dc.title | TANDEM study with thermoluminescent materials in standard diagnostic beams | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | ANA FIGUEIREDO MAIA | |
| ipen.autor | LINDA V. E. CALDAS | |
| ipen.codigoautor | 2991 | |
| ipen.codigoautor | 1495 | |
| ipen.contributor.ipenauthor | ANA FIGUEIREDO MAIA | |
| ipen.contributor.ipenauthor | LINDA V. E. CALDAS | |
| ipen.date.recebimento | 08-09 | pt_BR |
| ipen.identifier.fi | Sem F.I. | pt_BR |
| ipen.identifier.ipendoc | 12815 | pt_BR |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | de6ea8e6-1554-4d6d-b73a-40e3df506cd9 | |
| relation.isAuthorOfPublication | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| relation.isAuthorOfPublication.latestForDiscovery | 7f46d4f4-dfd6-4485-a767-10df5b4f4f13 | |
| sigepi.autor.atividade | MAIA, ANA F.:2991:-1:S | pt_BR |
| sigepi.autor.atividade | CALDAS, LINDA V.E.:1495:28:N | pt_BR |
Pacote Original
1 - 1 de 1