Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code

Carregando...
Imagem de Miniatura

Data

Data de publicação

Orientador

Título da Revista

ISSN da Revista

Título do Volume

É parte de

É parte de

É parte de

Brazilian Journal of Physics
Exportar
Mendeley

Projetos de Pesquisa

Unidades Organizacionais

Fascículo

Resumo
The present work shows the evaluation of the flux and absorbed dose rate of neutrons in a 241AmBe Irradiator at IPEN facilities using the MCNP-4C transport code. The geometry of the 241AmBe source as well as the Irradiator design, constituted of 2 neutrons sources, were modeled. In addition, four and eight sources of 241AmBe were also considered for checking the viability to increase the Irradiator performance. The results show an increase for both flux and absorbed dose rate, mainly for the fast configuration.

Como referenciar
ZEVALLOS CHAVEZ, J.Y.; ZAMBONI, C.B. Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code. Brazilian Journal of Physics, v. 35, n. 3B, p. 797-800, 2005. DOI: 10.1590/S0103-97332005000500020. Disponível em: http://repositorio.ipen.br/handle/123456789/5515. Acesso em: 30 Dec 2025.
Esta referência é gerada automaticamente de acordo com as normas do estilo IPEN/SP (ABNT NBR 6023) e recomenda-se uma verificação final e ajustes caso necessário.