Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code
| dc.contributor.author | ZEVALLOS CHAVEZ, J.Y. | pt_BR |
| dc.contributor.author | ZAMBONI, C.B. | pt_BR |
| dc.coverage | Internacional | pt_BR |
| dc.date.accessioned | 2014-07-15T13:48:57Z | pt_BR |
| dc.date.accessioned | 2014-07-30T11:46:27Z | |
| dc.date.available | 2014-07-15T13:48:57Z | pt_BR |
| dc.date.available | 2014-07-30T11:46:27Z | |
| dc.date.issued | 2005 | pt_BR |
| dc.description.abstract | The present work shows the evaluation of the flux and absorbed dose rate of neutrons in a 241AmBe Irradiator at IPEN facilities using the MCNP-4C transport code. The geometry of the 241AmBe source as well as the Irradiator design, constituted of 2 neutrons sources, were modeled. In addition, four and eight sources of 241AmBe were also considered for checking the viability to increase the Irradiator performance. The results show an increase for both flux and absorbed dose rate, mainly for the fast configuration. | |
| dc.format.extent | 797-800 | pt_BR |
| dc.identifier.citation | ZEVALLOS CHAVEZ, J.Y.; ZAMBONI, C.B. Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code. <b>Brazilian Journal of Physics</b>, v. 35, n. 3B, p. 797-800, 2005. DOI: <a href="https://dx.doi.org/10.1590/S0103-97332005000500020">10.1590/S0103-97332005000500020</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5515. | |
| dc.identifier.doi | 10.1590/S0103-97332005000500020 | |
| dc.identifier.fasciculo | 3B | pt_BR |
| dc.identifier.issn | 0103-9733 | pt_BR |
| dc.identifier.orcid | https://orcid.org/0000-0001-7766-2692 | |
| dc.identifier.uri | http://repositorio.ipen.br/handle/123456789/5515 | pt_BR |
| dc.identifier.vol | 35 | pt_BR |
| dc.relation.ispartof | Brazilian Journal of Physics | pt_BR |
| dc.rights | openAccess | en |
| dc.subject | americium 241 | pt_BR |
| dc.subject | beryllium | pt_BR |
| dc.subject | neutron flux | pt_BR |
| dc.subject | irradiation devices | pt_BR |
| dc.subject | dose rates | pt_BR |
| dc.subject | radiation doses | pt_BR |
| dc.subject | m codes | pt_BR |
| dc.subject | simulation | pt_BR |
| dc.subject | monte carlo method | pt_BR |
| dc.title | Evaluation of the neutron flux distribution in an AmBe irradiator using the MCNP-4C code | pt_BR |
| dc.type | Artigo de periódico | pt_BR |
| dspace.entity.type | Publication | |
| ipen.autor | CIBELE BUGNO ZAMBONI | |
| ipen.autor | JUAN YURY ZEVALLOS-CHÁVEZ | |
| ipen.codigoautor | 267 | |
| ipen.codigoautor | 3565 | |
| ipen.contributor.ipenauthor | CIBELE BUGNO ZAMBONI | |
| ipen.contributor.ipenauthor | JUAN YURY ZEVALLOS-CHÁVEZ | |
| ipen.date.recebimento | 06-01 | pt_BR |
| ipen.identifier.fi | 0.445 | pt_BR |
| ipen.identifier.ipendoc | 11166 | pt_BR |
| ipen.identifier.iwos | WoS | pt_BR |
| ipen.range.fi | 0.001 - 1.499 | |
| ipen.type.genre | Artigo | |
| relation.isAuthorOfPublication | 563d95e5-227e-456d-a1d7-4bb051ae51ba | |
| relation.isAuthorOfPublication | 126bf50d-81a5-46b3-bac6-e9a5350a9985 | |
| relation.isAuthorOfPublication.latestForDiscovery | 126bf50d-81a5-46b3-bac6-e9a5350a9985 | |
| sigepi.autor.atividade | ZEVALLOS CHAVEZ, J.Y.:3565:21:S | pt_BR |
| sigepi.autor.atividade | ZAMBONI, C.B.:267:6:N | pt_BR |
Pacote Original
1 - 1 de 1