Influence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodology

dc.contributor.authorKUAHARA, LILIAN T.
dc.contributor.authorCORREA, EDUARDO
dc.contributor.authorPOTIENS, MARIA da P.A.
dc.coverageInternacionalpt_BR
dc.creator.eventoINTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATIONS, 10thpt_BR
dc.date.accessioned2017-10-25T09:41:20Z
dc.date.available2017-10-25T09:41:20Z
dc.date.eventoJuly 09-13, 2017pt_BR
dc.description.abstractA safe and efficient Nuclear Medicine Services (NMS) performance depends, among other factors, on a complete quality assurance program, mainly in the case of the activity meters. Many elements may influence this equipment response, being the major errors related to vials characteristics, such as volume and geometry, as presented in other studies [1,2]. Correction factors must be applied in order to avoid patient exposure to excessive doses.However, another aspect that should be taken into account is how much radioactive material is lost during the radioisotope labeling, a process that includes many recipient changes.In this study we present the estimated activity lost during 99mTc labeling process and show how important is to add this value to the total activity measured in a new “in situ” calibration procedure, in which the activity meter is not removed from its place of use. For the radioactive residue determination99mTc labeling procedure was reproduced under laboratorial conditions, resulting in losses of up to 40 %. However greater errors are expected in a NMS. Activity meter calibration using two methodologies: the first consists in a direct comparison between the two systems with the same vial (P6-P6 and 10R-10R), and the second is a comparison made using two different vials (P6-10R), with and without geometry and residual activity corrections. A calibration factor of 0.999 was obtained in the reference situation. The same procedure performed without the application of the necessary correction factors resulted in a variation of almost 3 %, which is high considering the test was made under controlled conditions and less residue was left inside vials. The “in situ” calibration procedure worked well and was important to present the need of correction factors application, including the residue activity measurement.pt_BR
dc.event.siglaIRRMApt_BR
dc.format.extent65-65pt_BR
dc.identifier.citationKUAHARA, LILIAN T.; CORREA, EDUARDO; POTIENS, MARIA da P.A. Influence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodology. In: INTERNATIONAL TOPICAL MEETING ON INDUSTRIAL RADIATION AND RADIOISOTOPE MEASUREMENT APPLICATIONS, 10th, July 09-13, 2017, Chicago, IL, USA. <b>Abstract...</b> p. 65-65. Disponível em: http://repositorio.ipen.br/handle/123456789/27951.
dc.identifier.orcidhttps://orcid.org/0000-0002-4049-6720
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/27951
dc.local.eventoChicago, IL, USApt_BR
dc.rightsopenAccesspt_BR
dc.titleInfluence of the vials radioactive residue in Nuclear Medicine procedure applied to a new “in situ” activimeter calibration methodologypt_BR
dc.typeResumo de eventos científicospt_BR
dspace.entity.typePublication
ipen.autorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.autorEDUARDO DE LIMA CORREA
ipen.autorLILIAN TOSHIE KUAHARA
ipen.codigoautor346
ipen.codigoautor7498
ipen.codigoautor10859
ipen.contributor.ipenauthorMARIA DA PENHA ALBUQUERQUE POTIENS
ipen.contributor.ipenauthorEDUARDO DE LIMA CORREA
ipen.contributor.ipenauthorLILIAN TOSHIE KUAHARA
ipen.date.recebimento17-10pt_BR
ipen.event.datapadronizada2017pt_BR
ipen.identifier.ipendoc23261pt_BR
ipen.notas.internasAbstractpt_BR
ipen.type.genreResumo
relation.isAuthorOfPublication30f213ae-321d-4d51-8763-0a2585255fb9
relation.isAuthorOfPublication1f00087b-0c1b-413b-8464-2842b24a7328
relation.isAuthorOfPublication44381d85-6097-40f4-b9a3-9e991b7bebe5
relation.isAuthorOfPublication.latestForDiscovery44381d85-6097-40f4-b9a3-9e991b7bebe5
sigepi.autor.atividadeKUAHARA, LILIAN T.:10859:330:Spt_BR
sigepi.autor.atividadeCORREA, EDUARDO:7498:330:Npt_BR
sigepi.autor.atividadePOTIENS, MARIA DA P.A.:346:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
23261.pdf
Tamanho:
84.4 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: