A rotational calibration method using thermoluminescent dosemeters for dose determination in computed tomography beams

dc.contributor.authorMAIA, ANA F.pt_BR
dc.contributor.authorCALDAS, LINDA V.E.pt_BR
dc.coverageInternacionalpt_BR
dc.date.accessioned2014-07-15T13:44:15Zpt_BR
dc.date.accessioned2014-07-30T11:48:41Z
dc.date.available2014-07-15T13:44:15Zpt_BR
dc.date.available2014-07-30T11:48:41Z
dc.date.issued2008pt_BR
dc.description.abstractA procedure for calibration of thermoluminescent dosimeters, called rotational calibration, was developed to create a procedure more adequate for dose procedures used in computed tomography. Thermoluminescent dosimeters were rotated during irradiation to simulate the set-up used in dosimetric procedures in computed tomography equipment. Three commercial types of thermoluminescent dosimeters were calibrated using this methodology. The results showed that the measured values were lower when the dosimeters were irradiated with rotation than in a static geometry. Although the reading differences were not very large, they are not negligible, and they contribute to underestimating the dose.
dc.format.extent107-110pt_BR
dc.identifier.citationMAIA, ANA F.; CALDAS, LINDA V.E. A rotational calibration method using thermoluminescent dosemeters for dose determination in computed tomography beams. <b>Nuclear Instruments and Methods in Physics Research, B</b>, v. 266, n. 1, p. 107-110, 2008. DOI: <a href="https://dx.doi.org/10.1016/j.nimb.2007.10.008">10.1016/j.nimb.2007.10.008</a>. Disponível em: http://repositorio.ipen.br/handle/123456789/5106.
dc.identifier.doi10.1016/j.nimb.2007.10.008
dc.identifier.fasciculo1pt_BR
dc.identifier.issn0168-583Xpt_BR
dc.identifier.orcidhttps://orcid.org/0000-0002-7362-2455
dc.identifier.urihttp://repositorio.ipen.br/handle/123456789/5106pt_BR
dc.identifier.vol266pt_BR
dc.relation.ispartofNuclear Instruments and Methods in Physics Research, Bpt_BR
dc.rightsopenAccessen
dc.subjectthermoluminescent dosemeterspt_BR
dc.subjectcalibrationpt_BR
dc.subjectdosemeterspt_BR
dc.subjectcomputerized tomographypt_BR
dc.titleA rotational calibration method using thermoluminescent dosemeters for dose determination in computed tomography beamspt_BR
dc.typeArtigo de periódicopt_BR
dspace.entity.typePublication
ipen.autorLINDA V. E. CALDAS
ipen.autorANA FIGUEIREDO MAIA
ipen.codigoautor1495
ipen.codigoautor2991
ipen.contributor.ipenauthorLINDA V. E. CALDAS
ipen.contributor.ipenauthorANA FIGUEIREDO MAIA
ipen.date.recebimento08-03pt_BR
ipen.identifier.fi0.999pt_BR
ipen.identifier.ipendoc12284pt_BR
ipen.identifier.iwosWoSpt_BR
ipen.range.fi0.001 - 1.499
ipen.type.genreArtigo
relation.isAuthorOfPublication7f46d4f4-dfd6-4485-a767-10df5b4f4f13
relation.isAuthorOfPublicationde6ea8e6-1554-4d6d-b73a-40e3df506cd9
relation.isAuthorOfPublication.latestForDiscoveryde6ea8e6-1554-4d6d-b73a-40e3df506cd9
sigepi.autor.atividadeMAIA, ANA F.:2991:-1:Spt_BR
sigepi.autor.atividadeCALDAS, LINDA V.E.:1495:330:Npt_BR

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
12284.pdf
Tamanho:
237.44 KB
Formato:
Adobe Portable Document Format

Coleções